effectively improved by changing the header configurations.
In order to compare the flow distribution performance
of the three type header configurations, the
effects of header configurations on flow nonuniformity
(Si) are illustrated in Fig. 11. Both type B and type C
have better performance than the conventional type A
currently used in industry. The flow distribution