The LoLo Hot Plate ships with a ¾” NPT pipe nipple that extends from the right-rear of
the unit (when facing it). A gas pressure regulator is provided, ships loose and must be
connected by the installer.
1. The LoLo Gas Hot Plate must be connected to a reliable source of natural gas
delivered at a rate between the 6” water-column (WC) minimum and the 10”
water-column (WC) maximum pressures.
2. The gas pressure regulator (provided) must be connected to the ¾” NPT pipe
nipple.
3. A ¾” gas shutoff valve must be supplied and installed between the pressure
regulator and the building incoming gas supply line.
4. The incoming gas connection must be made to the shutoff valve via ¾”-14NPT
pipe or a code compliant flexible gas connector.
5. For liquid petroleum (LP) gas installations, all pipe thread compound used must
be resistant to the action of liquid petroleum gases.
6. Check ALL pipe connections for leaks using a liquid soap solution.