In the second part (Section 6) we included a pinch analysis for
the heat transfer from the heat carrier to the ORC working fluid by
an EHE. For a given inlet temperature Tin of the heat carrier we
searched for ORC working fluids and cycle conditions which give
aminimumvalue of the heat capacity flowrate C_ for the production
of 1MW net power output.