where m is irrigation water amount per irrigation (mm); a is
percentage of consumptive water to field capacity(uf), a = 40%;
umax is the upper limit of irrigation (72% uf); umin is the lower
limit of irrigation (60% uf); p is ratio of soil wet zone, p = 40%
according to the pre-experimental data, H is depth that irrigation
penetrates (1 m).