Reversing the direction of rotation
• To reverse the direction, interchange the leads of either the
auxiliary or main winding
• For split phase and capacitor start motor, the direction cannot
be reversed while motor is running
• For capacitor-run motor, the rotation can be reversed using the
double-throw switch (switch C series from one to another
winding)