Let us consider the correlation field of the “ultrasonic signal amplitude–lack-of-fusion depth” regression (Fig. 1) which can be obtained from the results of ultrasonic testing and opening of welded seams (the results of opening showed that lacks of fusion are the most widely spread dangerous inner flaws in welded joints of lifting structures detected in ultrasonic testing).