CONCLUSIONS: Needle decompression of suspected tension pneumothorax should be attempted in the MHL at the level of the sternal angle using a needle at least 7 cm long inserted perpendicular to the horizontal plane. This approach should yield the highest success rate and margin of safety compared with other sites.