From the hygroscopic tests, the best-fitting curves based on
analytical functions have been obtained. Compared the
experimental results with the Künzel model, Kumaran
model and Cubic function, the best fitting parameters in
each one of them have been calculated. As a consequence,
it is shown that the Kumaran model and Cubic function
are suitable to reproduce the actual hygroscopic behaviour
of soil-based foamed concrete.