Testing a similar condition to the solar illumination, all
the LEDs of the simulator were driven at full power, in order
to emulate the solar spectrum. The results are presented in
Figure 10. To compare this result with a standard IxV curve,
the current and voltage of the E-17 PV module were
modified with the same variable load, 700 Ω, in the condition
of 1000 W/m². This result can be seen in Figure 11. In both
tests, the temperature was kept constant at 25 ºC.