Two and three hole samples showed an 11% and 12% increase respectively in joint strength compared to the average ultimate strength of similar 3 s dwell time samples. This shows an additional way to create stronger joints by distributing the load between multiple pins without increasing dwell time. Additional configurations and geometries such as hole shape, hole location, inclusion of threads in the hole, tapers, etc. may also lead to additional increases in strength.