Scalar modulation methods
A second type of MC modulation based on a low-frequency transfer matrix is the
scalar method. The basic rules of this control were first proposed by Roy, in 1987
[113]. In the proposed modulationmethod the switch actuation signals are calculated
directly from measurements of the source phase voltages. According to [111–113],
the value of any instantaneous load phase voltage may be expressed by the following