Thank you very much for your section’s support every day.
We are also bothered this machine every day. As you know, this line caused trouble especially January.
At that time, our section detected some phenomenon at the time of trouble.
1) Broken Mini Filter
2) Teflon Pipe Breakage
3) Attached FS on products surface
4) Different Ink Discharge Amount for each gear pump (Not Follow Set value)
>>> Already exchange new pump and adjust ink amount by Banpot
5) Nobody knows filter mesh (Original 75um, but …….)
According to Fuji Machinery after informing this incident, root cause may be jamming inside piping.
Piping Jam, Broken Air Cut Valve, valve motion abnormal and etc.
Anyway, our section will be held PM at RS-1.
We will confirm piping system again following attached file received from maker.