Pressure Surges: While carrying out ballasting /de-ballasting operation the pumps in use are mostly of centrifugal type. To start a centrifugal pump, positive suction pressure must always be kept in mind. The discharge valve of the pump can be kept upto 30% open to prevent damage to the valve body or valve seat ring