Select DC1 format and press [ENT] to view the DATA SEND. CONFIRMATION screen. (Same procedure is performed for AUX format.)
Press [ENT], and set the PC to be ready to receive.
4.3.3 Communication setup
The communication parameter is set when stored data is received or sent between the instrument and the PC etc.
4.3.3.1 Receiving data setting
Select the 4. DATA SETUP and press [ENT] to view the DATA SETTING.
[1. RECEIVE RECT. DATA]
Select the 1. RECEIVE RECT. DATA and press
[ENT] to view the following screen.
Press [ENT] to open the selection window. Select each setting and press [ENT].
Press [ACCEPT] when all selections are made.
• DISP.# AXIS: BASIS DIRECT., RIGHT ANGLE, or HEIGHT is selected when data is
transferred between the TS and PC. (cfr. “5.5.2 Coordinate axis definition”)
They are used for matching coordinate system between definition in the instrument and definition in the external device when they are different. However, it is necessary to
match the definition of the “Coord. Axis” between settings in “Communication setup” and
settings in “Coordinate axis definition” when same coordinate systems are used.