Based on 6000 flash records from different regions of the world, the distribution of
the number of strokes per flash for downward negative flashes per Anderson and
Eriksson [7] is give in Table 7. The median of the distribution is 2 and the mean or
average value is 3. As stated before, almost universally, there is only one stroke per
flash for positive polarity flashes