Figure 6 shows the average collected deposits on the four
sample rings. The amount of deposits was about 25% higher
for the pellets with additives compared to the reference pellets
and the commercial pellets. The fly ash production was much
higher in the cases with additives compared to the reference
case, as the heat exchanger tubes were covered with a white
layer of fly ash particles (Figure 7).