Test method
Set the test piece on a regular test stand.
(1) adjusting screw with fixed it compulsively using a torque wrench device in directions
and fixed torque 2.5 Nm (25 kgf.cm)
(2) Loads 300 N (30 kgf) at adjusting screw, using a dial gauge measuring the deflection after loading.
Assessment criteria
(1) Adjusting torque screw with fixed standard 2.5 Nm (25 kgf.cm)
(2) Shall be no the deflection greater than 3 mm under the loading.
Test report
(1) After test, leveling torque screw with fixed be no in line with standard.(RH,LH)
(2) After test, no the deflection greater than 3 mm under the loading.