While, the indicator of the 10/13th rule would alert the
designer to conduct a dynamic analysis to determine the degree
of the overpressure of a given heat exchanger, in some cases this
rule is satisfied, but the connecting upstream and downstream
piping system may be subjected to an overpressure above their
design rating, and hence a dynamic simulation must be performed
to determine appropriate design pressures for these
systems.