In practical applications, when the calorific value of the waste is less than 5000 kJ/kg and the deviation from MCR is large, the temperature of the furnace cavity is low, and the injection of secondary air will significantly reduce the temperature of the furnace. Therefore, some incineration plants have taken measures to reduce or even intermittently inject secondary air to increase the furnace temperature.