after investigation, we found that seal ring was wear due to seal's contact surface got high temperature. it is possible that the used liquid was not LLC, but it was water because the boiling temperature of LLC is higher than water. then, after the seal ring wear, it get the liquid flow into bearing and then the liquid would mix with grease.