10. STABILITY AND REACTIVITY
REACTIVITY: May react with evolution of heat on contact with water.
CONDITIONS TO AVOID: Avoid heat, flames, sparks and other sources of ignition. Minimize contact with material. Avoid inhalation of material or combustion by-products. Keep out of water supplies and sewers.
INCOMPATIBILITIES: combustible materials, bases, amines, oxidizing materials, acids
HAZARDOUS DECOMPOSITION: Thermal decomposition products: cyanides
POLYMERIZATION: Polymerizes with evolution of heat. Avoid contact with air, light, water, incompatible material or storage and use above room temperature.
11. TOXICOLOGICAL INFORMATION
HYDROGEN CYANIDE, ANHYDROUS, STABILIZED:
TOXICITY DATA: 150 ppm /30 minute(s) inhalation-rat LC50; 3700 ug/kg oral-mouse LD50
LOCAL EFFECTS: Irritant: inhalation, eye
ACUTE TOXICITY LEVEL: Highly Toxic: inhalation, ingestion
TARGET ORGANS : blood
MEDICAL CONDITIONS AGG
RAVATED BY EXPOSURE: blood system disorders, heart or cardiovascular disorders, nervous system disorders