The use of arithmetic
mean temperature for air across the bed, to determine the
heat transfer coefficient, was primarily motivated by the
lack of information regarding variations in air temperature
within the bed, and led to over-estimation of grain temperature,
whilst the over-estimation of exit air temperature
was mainly due to the heat loss effect.