The nominal bending strength (Mn) of the eccentrically loaded specimens in Fig. 15
was determined by the limit state of flange local buckling. As shown in the bottom of Table 2, the flange exceeded the compact section limit by about 10% while the web was very compact with a normalized slenderness of 1.14, orwellwithin the compact section limit of 3.76.