The initial rational for inspecting girth welds on CRA overlay clad pipes or any bimetallic girth weld was to inspect several zones of the weld using a series of ultrasonic beams placed at different angles. One problem with this technique is that high angle longitudinal beams (over
70°) are very difficult to control, calibrate, and analyze, which gives rise to a blind zone in the
upper part of the weld.