Settling time The settling time ts is used as a measure of the time taken for the oscillations to die away. It is the time taken for the response to fall within and remain within some specified percentage of the steady-state value (see Figure 4.1). Thus for the 2% settling time, the amplitude of the oscillation should fall to be less than 2% ofyss. We have: