The suction pressure range of the liquid ring pump will be reduced further by the preconnected
gas jet ejector corresponding to the designed data. As a rule, the continuous
in-flow of motive air prevents the liquid ring pump from operating in the cavitation range.
The gas jet ejector can be designed for:
a.) atmospheric air as motive agent;
b.) circulating gas as motive agent which, after being compressed to atmospheric
pressure by the liquid ring pump, is re-supplied to the gas jet ejector.
NOTE!