1) Application: This manual applies to draw dies (X2) with cushion among dies allocated to press machines that attached cushion pin equalizing unit to die cushion device (X1) (*1) Air Die Cushion and Servo Die Cushion (X2) Including the die combined with nitro-tanker 2) Content: Make sure that relativity of number of cushion pins and cushion load is within "pressure equalization region" and "usable range of characteristic line of pressure equalization. [Fig. 11[Fig. 21 3) Method: Make sure that relative points are within "pressure equalization region" and "usable region" by applying number of cushion pins and cushion pressure to characteristic line of pressure equalization diagram in each line specification. 4) Standard O In both upper and lower limit pressure of FAT. relative points shall be within pressure equalization region (except C-servo) O Relative points of standard pressure shall be within usable region. (only c-servo) 5) Evaluation: If all standards are followed, a circle (O) is given. If some standards are not followed, given. (Deduct five points]