▷ It determines the following characteristic for a position order of acceleration and deceleration.
▷ In case that PF value is small, the total motion time becomes delayed.
Therefore, it is required to adjust when you intend to reduce a cycle time.
▷ It is possible to make vibration or noise in the mechanical part when the settings is increased.
▷ Adjusting range : 0.0 ~ 0.30 (recommended that you adjust it with a unit of 0.01.)
▷ Default value : 0.1