The limits of SNIP are that it is also effort dependent. In
patients with obstructive lung disease, such as cystic fibrosis,
SNIP unlike Pimax underestimates strength because SNIP is
a short manoeuvre associated with a dampening of the
transmission of the pressure response from the oesophagus
to the mouth and nose