Gas Tungsten Arc Welding
8.4.1 The use of flux backing or flux cored GTAW wires for the root pass of single-sided welds without backing in-lieu of a backing purge gas (refer to paragraph 8.6.2) shall be subject to Owner review and approval.
8.4.2 The use of activating flux (A-TIG) shall be subject to Owner review and approval.