Machine: 140K S/n: SZL01282 SMU 9208 hr.
Complaint : Found fault alarm transmission show on monitor after Install new position sensor,
Checked: Fault code on ET.
• 573- 4 Inching Pedal Position Sensor : Voltage Below Normal.
Cause: The sensor gp position P/n: 266-1467 is internal malfunction.
Correction: Replacing new P/n: 266-1467 sensor gp position.
Last repair by customer invoice number DPL-901852 and invoice date 17 Oct,2016
At SMU 9203.
It failed just period to install.