IMMEDIATE ACTION:
The Truck was tagged 'Out of Service' pending replacement of the truck or repairs to door fixtures.
NT WorkSafe Notified
ROOT CAUSE:
Failure of maintenance / inspection system to detect / repair defective door handle
CORRECTIVE ACTIONS:
1. Toolbox crew members on the requirement of inspecting and reporting and placing appropriate tags on all
plant and equipment that are found to have deficiencies.
2. Ensure all plant and equipment that require monthly servicing are completed as required, including the
completion of a complete inspection report of the plant or equipment by the responsible Fitter.
3. Both aging Water Trucks will be demobilised and replaced with new trucks at the earliest opportunity.