After the pump has been disassembled and cleaned, inspect the pump gears or rotors for chipping, galling, pitting, or signs of abnormal wear. Examine the housing bores for similar signs of wear. If any part of the housing is scored or noticeably worn, replace the pump as an entire assembly.