13.2 Calculation for Procedure D:
13.2.1 Calculate the MFR for each capture at each test load
in accordance with Section 10 (Procedure B).
13.2.2 If the differences between the individual melt flow
rates at each test load are no greater than 63 %, calculate the
average Melt Flow Rate for each test load. If differences are >
63 % repeat the test.