Where di is the distance from the i th measurement location to the reference point,
and Er and Nr are the coordinates of the reference point and Ei and Ni are the
coordinates of the i
th
measurement point. Using Equation 3.1, a new table is
generated containing the receive signal power in dBm against distance in ascending
order. The table is then plotted x distance and y receive signal level.