The control parameters include time, temperature and gas dissociation rate. In production environment, the latter is periodically measured and adjusted. The inherent feature of conventional gas nitriding is that the superficial concentration of nitrogen cannot be precisely monitored. As a result the structure of nitrided layer and the entire process are often missing predictability and repeatability.