The power output of a gasification cook stove depends on the cross-sectional
area of the reactor. In the design presented in this report, that area is the area
of the circular inner cylinder. Using the previously calculated requirement
for Fuel Consumption Rate (FCR), the minimum diameter of the stove can
be found using the Specific Gasification Rate (SGR) with the relation in
Equation