The packages are weighed back at weekly intervals
and the gain in weight, along with the original
moisture determination, are then used to calculate
the moisture changes. From the moisture sorption
curve developed for the product and knowledge of
the package material water vapor transmission rate
(WVTR), a calculation can be made to determine its
shelf life.