In order to measure the relaxed strains associated with incremental slitting, a type UBFLA-03 strain gauge with a gauge length of 0.3 mm, supplied from TML Co., was used. In order to minimize the effect of averaging of the strain over the gauge length and to increase the precision of strain readings at the desired location, a small gauge was selected.