1. For residential uses, any lamp type with output of 1,000 lumens or more shall be fully
shielded. If multiple lamps of less than 1,000lumens are used, and the total lumens are
greater than 1,000 lumens in total then shielding is required.
2. Lighting for multiple household dwellings is not considered residential, and must comply
with all requirements for Non-Residential lighting, including, but not limited to lumen
caps and curfews for decorative lighting.
3. All light fixtures located within 25-feet of the property line adjacent to a residential use
shall use fully shielded luminaries.
D. Shielding and Curfew Requirements for Non-Residential Uses
1. All non-residential light fixtures except for unshielded signs shall be fully-shielded.
2. Any Class 1 (Color Rendition), Class 2 (General Illumination), or Class 3 (Decorative
Illumination) lamp type shall be shielded in accordance with Table 4.1.
3. All Class 1 (Color Rendition) and Class 3 (Decorative Illumination) lighting shall be
extinguished between 11 p.m. (or when the business closes, whichever is later) and
sunrise, except: