All four repeats of the base case experiment produced consistent
results. Calculating 95% confidence intervals assuming a
logarithmic distribution of random error, the mean average peak
temperature was 543 ± 15 ◦C and the mean propagation velocity
was 0.54 ± 0.10 cm/min. These estimates of uncertainty were
assumed to apply to all subsequent experiments.