Subjects were prompted to elicit contractions corresponding
to the target motion class displayed in a video.
Each movement contraction was sustained for 4 s to
generate myoelectric signals and the rest time between
subsequent contractions was 5 s. Each of seven movements
was repeated 10 times per set. Thus each set produced
40-sec EMG and ACC-MMG recordings per
movement. To avoid muscle and mental fatigue, subjects