In the numerical simulations, the total overlap length L of the bond, total specimen length 2d – L , height h of the specimen, and thickness t of the adhesive were kept constant. Varied quantities included geometric parameters such as tooth height and width, adhesive Young's modulus (Section 3), and length of sections of interface with no bonding to simulate existence of crack (Section 4).