The above result indicates an alternating stress induce is
78.6N/mm2 which is less then the allowable fatigue limit of
86.2 N/mm2, so The camshaft is safe for 1 million cycles.
But the value of 1 indicates minimum safety factor in the
estimation suggesting the necessity for either material improvement
or increase number of supports.