So the keyword for producing the voltage of induction generator has 2 keywords. The first keyword is
the residual flux that it is collected within the core and also really small. The second keyword is the capacitor
connection to the armature winding that it has shown in Fig. 5 (a). Due to the flux needs reactive power
and the capacitor can supply the reactive power.