The model calculated product size distribution is compared
with the measured one. The sum of squares between the calculated
and measured product size distribution is used to control the
model fitting process. If the difference between the calculated
and the measured value is larger than the convergence set point,
the selection parameters will be adjusted, and the size reduction
process is iterated until the sum of squares between the calculated
and measured product size distributions is smaller than the convergence
set point.