Enough capacity to meet required turn over rate with at least one pump standby.
Flow meter provided.
On raised plinths.
Reasonable condition (leaks, vibration etc.)
High level alarm on balancing tank.
A minimum turnover rate of six hours (four times per day) is required, four-hour for children's pool.
All overflow systems has surge capacity of not less than one gallon for each square foot of pool sqf of pool surface area.
Disinfection system shall be liquid chlorine or ozone or salt chlorination system with fully autmatic monitoring and dosing.
PH and Chemical control equipment shall be provided as Automatic PID Control
Standard test kits shall be provided for free chlorine residual and pH
A.E.D is prominently displayed on pool deck
Adeuate barrier (meets international regulations) to separate childrens and main pool is provided.
There are adequate depth indicators
Emergency direct dial phone on pool deck to 24/7 manned position.
ELCB circuit interrupters of 10 mA 30 sec shall be provided on pool circuits in the pool plant room.
Only 12v or lower ELV electrical fittings are permitted within 3 m of the pol
ELCB circuit interrupters of 10 mA 30 sec shall be provided on all lighting and electrical circuits within 3m the pool.
Within 3 m from the pool edge all power outlets are not allowed.
All panel boards are in adequate condition
An eye wash bottle stations prominently displayed at pool deck
An eye wash bottle station is prominently displayed at pool deck
A first aid kit is prominently displayed on pool deck