6.3 Average
The HE lite is equipped with an aver- age function, allowing you to calculate automatically the average of up to six measurements. This function is particularly useful, in case of very different conditions (close to the forest, bottom of valleys, etc.) in order determine the average of the moisture reading to be expected.
For the setting of the average function please proceed as follows:
Select the function Average and confirm by pressing „AV f. Meas“ means the number of measurements included in the calculation (adjustable from 1 to 6; factory setting „0“, i.e. the average calculation is switched off).
„at Display“ means the number of measurements of one product which are indicated simultaneously (adjust- able as a function of “AV f. Meas“). Figure „1“ means just the same indication as it is during the standard measurement, only the last reading and the number of values included in the average calculation are indicated. Figure “2” to “6” means that all single readings included in the average reading are indicated during the measurement (see picture page 19). In both cases the average reading is
indicated in the line before last next to
the selected product.
The following paragraph describes
the procedure of the average function and the simultaneous presentation of
3 measurements:
Change the „„AV f. Meas“ to „3“ by mean of the left button two parameters are indicated on the display.