Eccentric braced frames can be configured in various forms as long as the brace is connected to at least one link. The underlying principle is to prevent buckling of the brace from large overloads that may occur during major earthquakes. This is achieved by designing the link to yield prior to distress in other structural elements. The most efficient (but also the most obstructive) types of bracing are those that form a fully triangulated vertical truss.