Once the shear reinforcement design is completed, the next
step is to check for shear-friction resistance at any construction
joints where concrete is placed against hardened concrete. If
additional reinforcement is required, either reinforcement
ratio rl can be increased or dowels can be added at the
construction joint. See Section 5.5.